2011/03/03 Failed. Conservation annual inspection #9987584

** Special Note: An annual inspection was performed in 2012, also reported as failed, but no details were noted. Given the life safety issues noted in the 2011 inspection, we placed it to be visible to you. **

VIOLATIONSBUILDING CODE CITATIONVIOLATION DETAILS
CN031013Failed to install approved fire extinguishers on every floor of residential building more than three stories in height and having floor area exceeding 3,000 square feet. (15-16-160, 15-16-640)FIRE EXTINGUISHERS – SOME AREA’S MISSING IN STAIRWAYS – 4 WEST, 2 WEST, 2 EAST
CN031013Failed to install approved fire extinguishers on every floor of residential building more than three stories in height and having floor area exceeding 3,000 square feet. (15-16-160, 15-16-640)Interior corridors/ stairs missing fire exstinguishers.
CN031023Failed to maintain properly charged fire extinguisher and to attach tag which clearly indicates recharge date and signature of the person who performed the recharge. (15-16-680)Intrerior corridors/ stairs the few fire exsinguishers installed exspired,not charged and missing tags.
CN031023Failed to maintain properly charged fire extinguisher and to attach tag which clearly indicates recharge date and signature of the person who performed the recharge. (15-16-680)FIRE EXTINGUISHERS THRU-OUT MISSING TAGS
CN061014Failed to maintain the exterior walls of a building or structure free from holes, breaks, loose or rotting boards or timbers and any other conditions which might admit rain or dampness to the walls. (13-196-530(b), 13-196-641)REAR AT GRADE EXTERIOR PARKING AREA – MISSING AND LOOSE TILES
CN066034Failed to maintain balcony in good repair and free from cracks and defects. (13-196-530(e), 13-196-641)SPALLING CEMENT UNDER 5TH FLOOR BALCONIES, EXPOSED REBARS front and rear.
CN067014Failed to maintain roof in sound condition and repair, watertight and free from defects. (13-196-530, 13-196-530(c) and 13-196-641)5TH FLOOR WEST ROOF HATCH IS MISSING
CN101015Failed to maintain interior walls and ceilings free from holes or cracks. (13-19-540(c))FIFTH FLOOR CORRIDOR CEILING HAS WATER DAMAGED AREA – BLISTERING PAINT – ALSO 2ND FLOOR CORRIDOR WALLS AND CEILINGS.
CN105035Repair or replace door hardware. (13-196-550)INTERIOR STAIRWAY 4 EAST BROKEN HINGES ON DOOR
EL0027Restore exit and emergency lighting system and related equipment to operable condition. (18-27-700.6)EMERGENCY BACKUP BATTERY LIGHTING – BATTERIES DEAD