3517-25 North Racine Avenue

Registered As

Still investigating.

Recent Inspections

View Full Building Record as of 5/5/2020 (PDF)

2010/04/08 Failed. Conservation Annual Inspection #9711683

VIOLATIONSBUILDING CODE CITATIONVIOLATION DETAILS
CN061014Failed to maintain the exterior walls of a building or structure free from holes, breaks, loose or rotting boards or timbers and any other conditions which might admit rain or dampness to the walls. (13-196-530(b), 13-196-641)North at 3525 / rear exit: Cracks around lintel area. South at grade: Walls open mortar joints. East at 1st floor N.E and S.E. porches: Walls spalling and open mortar joints.
CN061034Failed to maintain all interior walls, ceilings and interior woodwork free of flaking, peeling, chipped or loose paint, plaster or structural material. (13-196-540(d), 13-196-641)Window frames, sashes and rear porch systems flaking paints.
CN065014Failed to maintain lintel in good repair and free from cracks and defects. (13-196-530(e), 13-196-641)3523 and 3535 / Porch exit: Rusting and sagging lintels. Repair permit required.
CN065034Failed to maintain window sill in good repair and free from cracks and defects. (13-196-530(e), 13-196-550, 13-196-641)1-3 / Flr: Window sills open mortar joints.
CN070024Failed to repair or replace defective or missing members of porch system. (13-196-570, 13-196-641)3517, 3519, 3523 and 3525 / Rear porch systems: Floor and landing joists are toe nailed to header joists thru-out. Stringers missing bolts to masonry walls. Guardrails only 32″ high. Treads and risers worn out. Permit only required for repairs.
CN070034Failed to rebuild or replace dilapidated and dangerous porch. (13-196-570, 13-196-641)3521 / Northeast and southeast porches:Columns erected on sidewalks with no concrete bases – foundation status unknown. Undersized 4×4 columns butt jointed, rotting and spaning 3 floors. 6×6 columns are overnotched and out of plumb with inadequate half-lap joints. Floor joist at various locations are toe nailed to header joists – missing hangers. Stringers are inadequately connected to columns – nailing only. Decks are weak with rotting, loose and buckling up boards. Railing sections are undersized with loose and rotting pickets.Treads and risers worn out. Entire porch structures are unstable and swaying. Full plans and permit are required to replace both porches.
CN138106Remove and stop nuisance. (7-28-060)BBQ grills on deck.
CN196029Post name, address, and telephone of owner, owner’s agent for managing, controlling or collecting rents, and any other person managing or controlling building conspicuously where accessible or visible to public way. (13-12-030)Bldg. missing owner’s I.D. sign.
CN198019File building registration statement with Building Dept. (13-10-030, 13-10-040)Bldg. not registered for 2010.