Registered As
Currently investigating.
Recent Inspections
View full building record as of 05/06/2020 (PDF)
2016/09/12 Failed. Conservation inspection #10563502.
See details below.
VIOLATIONS | BUILDING CODE CITATION | VIOLATION DETAILS |
---|---|---|
CN061014 | Failed to maintain the exterior walls of a building or structure free from holes, breaks, loose or rotting boards or timbers and any other conditions which might admit rain or dampness to the walls. (13-196-530(b), 13-196-641) | East – Thru-corridor – Hole in ceiling |
CN070014 | Failed to maintain exterior stairways in safe condition and in sound repair. (13-196-570, 13-196-641) | South, west, east elevations – Handrails missing from grade to basement |
CN070024 | Failed to repair or replace defective or missing members of porch system. (13-196-570, 13-196-641) | West, east elevations – Rear porches – Scuttle panels missing at 3rd floor levels; peeling paint at 3rd floor ceilings |
CN074024 | Failed to provide porch which is more than two risers high with rails not less than three and one-half feet above the floor of the porch. (13-196-570(b), 13-196-641 | South – Guardrails missipng at grade for basement areaway |
CN076034 | Failed to maintain roof gutters in good repair and working condition. (13-196-590, 13-196-630(b), 13-196-641, 18-29-1101, 18-29-1105, 18-29-1106) | North – Gutter – Holes; rusting |
CN076044 | Failed to maintain roof downspouts in good repair and working condition. (13-196-590, 13-196-630(b), 13-196-641, 18-29-1101, 18-29-1105, 18-29-1106) | West – Downspout – Paint peeling thru-out |
CN104015 | Replace broken, missing or defective window panes. (13-196-550 A) | North – Basement – Windows – Boarded with rotting plywood |
CN190019 | Arrange for inspection of premises. (13-12-100) | Interior of building – no response. Unable to inspect interior, stairwells, apartments, basement, all rear porches, and specifically Unit #620-Basement for complaint of holes and flooding issues. Unverified detectors and conditions. |
CN190020 | Arrange for entry to inspect construction work authorized by recently issued building permit. (13-12-100) | West, north, east elevations – Recently built rear porches per Permit #100459588 (issued 10/23/2012). Plans and permit not available for inspector’s review at time of inspection. |
EL0029 | Remove exposed wiring. (18-27-300.4) | East – Open junction boxes; covers missing; wires exposed |
EL0036 | Install cover on outlet or junction box. (18-27-370.25) | East – Open junction boxes; covers missing; wires exposed |
Photos Submitted by Users
None currently.
Reviews of Building